PTS-Master forecourt controller for petrol stations

PURPOSE

PTS-Master is a petrol station forecourt controller and is intended to provide control over standard forecourt equipment of petrol stations, lead sales of fuel through fuel dispensers, register all data on operations in internal database, provide remote configuration, diagnostics and reports reception using a built-in WEB-server.

PTS-Master forecourt controller is intended as for autonomous application at petrol stations (without a POS system), so as for implementation into software of third-party POS-systems with a purpose for provision of control over petrol station forecourt equipment, thus allowing general purpose POS systems to make sales of petroleum and all required operations at petrol stations.


Fuel card management system for petrol stations
Click on a scheme to enlarge


STRUCTURE

PTS-Master forecourt controller contains a CPU board, hard drive with database, PTS controller over fuel dispensers and ATG systems for petrol stations, interface converters for fuel dispensers, Wi-Fi module (in case if required) for connection with a remote small payment terminal. List of supported equipment can be expanded at request.

Software of PTS-Master forecourt controller contains MySQL database, which leads a table of petroleum products sales. PTS-Master forecourt controller allows the following possibilities for third-party POS systems:

  • provide dispensing of fuel through fuel dispenser
  • receive from a database content of sales table
  • register volume of fuel receptions into tanks of petrol station
  • receive current levels and volume of fuel in tanks (and additional measurement parameters)
  • receive information from RFID-cards for realization of required loyalty policies in a POS system at sales of fuel
  • receive various reports on operation of a petrol station

 For configuration of PTS-Master forecourt controller a separate WEB-application is used. Access to it is gained through a standard WEB-browser. Configuration allows setting of necessary parameters of connected equipment as locally through Ethernet, so as remotely (from a company office). In addition control over fuel dispensers and reporting can be done using WEB-interface.


DEVELOPERS' API, SOURCE CODES AND EXAMPLES

PTS-Master forecourt controller for developers is supplied together with full API (application programming interfaces) for mostly used programming languages and operation platforms.


   Ask YOUR questions about
"PTS-Master forecourt controller for petrol stations"

  Message is being sent... Please wait.

Other products of section:

Wireless forecourt communicator WFC
Wireless forecourt communicator WFC

Wireless forecourt communicator WFC allows communication with any brand of dispensers (fuel, LPG, CNG), tank probes and consoles, price poles in a wireless way without a need to put any cables. WFC has a rich set of electric interfaces on board (RS-485, RS-232, 2/3/4-wire current loops, voltage)

GB dispenser interface converter
GB dispenser interface converter

GB interface converter (RS-485/RS-232 to 2-wire current loop and backwards) is intended for communication with fuel dispensers, which use 2-wire current loop interface, through interfaces: RS-232, RS-485 (2 wires) GB

TH dispenser interface converter
TH dispenser interface converter

TH interface converter (RS-485/RS-232 to 3-wire current loop and backwards) is intended for communication with fuel dispensers, which use 3-wire current loop interface, through interfaces: RS-232, RS-485 (2 wires) TH

HY dispenser interface converter
HY dispenser interface converter

HY interface converter (RS-485/RS-232 to 4-wire current loop and backwards) is intended for communication with fuel dispensers, which use 4-wire current loop interface, through interfaces: RS-232, RS-485 (2 wires) HY

NP dispenser interface converter
NP dispenser interface converter

NP interface converter (RS-485/RS-232 to 4-wire current loop and backwards) is intended for communication with fuel dispensers, which use 4-wire current loop interface, through interfaces: RS-232, RS-485 (2 wires) NP

LP dispenser interface converter
LP dispenser interface converter

LP interface converter (RS-485/RS-232 to 3-wire current loop and backwards) is intended for communication with fuel dispensers, which use 3-wire current loop interface, through interfaces: RS-232, RS-485 (2 wires) LP

NZ dispenser interface converter
NZ dispenser interface converter

NZ interface converter (RS-485/RS-232 to 2-wire voltage driven circuit and backwards) is intended for communication with fuel dispensers, which use 2-wire voltage driven circuit interface, through interfaces: RS-232, RS-485 (2 wires)

NA dispenser interface converter
NA dispenser interface converter

NA interface converter (RS-485/RS-232 to non-addressable RS-422/RS-485/RS-232 and backwards) is intended for communication with fuel dispensers, which do not have a communication address in communication protocol and use one of the interfaces RS-422, RS-232 or RS-485 through interfaces:

RS-485 to RS-232 dispenser interface converter
RS-485 to RS-232 dispenser interface converter

RS485-4 dispenser interface converter (RS-485 to RS-232 interface and backwards) is intended for communication with fuel dispensers, which use RS-232 interface, through interfaces: RS-232 RS-485 (2-wire) Due to a reason that RS

Wireless interface converter RFC
Wireless interface converter RFC

Wireless interface converter RFC for petrol stations is appointed for establishing of wireless communication between devices having interfaces RS-232 and RS-485. RFC converter does not bring any changes to exchanged data between devices. Thus, RFC interface converter is a complete anal

USB to RS-232 interface converter
USB to RS-232 interface converter

USB to RS-232 interface converter is intended for conversion from USB interface (USB 1.1, USB 2.0) into two independent RS-232 interfaces in duplex and half-duplex modes of data exchange.USB to COM-port interface converter is based on FTDI chip and provides reliable operation 24/7.